2.
Indian Heart J ; 2002 May-Jun; 54(3): 309-11
Article in English | IMSEAR | ID: sea-5729

ABSTRACT

Strokes following cardiac surgery occur in about 5% of patients. Intra-arterial thrombolysis is a good option in such a setting where intravenous thrombolysis is contraindicated, and when in-hospital strokes are detected well within the window for treatment and the chances of complete reperfusion are maximum. On postoperative day 4 after atrial septal defect correction, a 34-year-old woman with paroxysmal atrial fibrillation developed left middle cerebral artery stroke causing severe neurological deficits. Intra-arterial thrombolysis with urokinase led to remarkable recovery.


Subject(s)
Adult , Cerebral Angiography , Female , Fibrinolytic Agents/therapeutic use , Heart Septal Defects, Atrial/surgery , Humans , Postoperative Complications/drug therapy , Stroke/drug therapy , Thrombolytic Therapy/methods , Treatment Outcome , Urokinase-Type Plasminogen Activator/therapeutic use
3.
Indian Heart J ; 2001 Nov-Dec; 53(6): 769-72
Article in English | IMSEAR | ID: sea-5316

ABSTRACT

Aneurysm of the peripheral pulmonary arteries is rare. Rupture of pulmonary artery aneurysms manifesting as recurrent hemoptysis with exsanguination is well recognized. We report the case of a young woman who presented with massive hemothorax and shock at the sixth month of pregnancy due to a ruptured lingular artery aneurysm. She was treated with selective coil embolization of the lingular artery to achieve hemostasis. Subsequently, clot evacuation from the pleural space was done. This case is reported for its unsuspected presentation, rarity and to highlight the use of catheter coil embolization to achieve control of bleeding and exclusion of the aneurysm from the pulmonary circulation.


Subject(s)
Adult , Aneurysm, Ruptured/complications , Embolization, Therapeutic , Female , Hemothorax/etiology , Humans , Pulmonary Artery/pathology
4.
Indian Heart J ; 2001 Jul-Aug; 53(4): 490-2
Article in English | IMSEAR | ID: sea-4601

ABSTRACT

Coronary artery disease involving both coronary ostia (left main and right coronary) is extremely rare in a premenopausal female, without pre-existing coronary risk factors. We report a case of tight bilateral coronary ostial disease which presented in unusual clinical circumstances in a young female, which was successfully revascularized by single-stage aorto-ostial cutting balloon angioplasty and stenting.


Subject(s)
Adult , Angioplasty, Balloon, Coronary , Aortic Diseases/diagnostic imaging , Coronary Stenosis/diagnostic imaging , Female , Humans , Stents
5.
Indian Heart J ; 1989 Mar-Apr; 41(2): 114-8
Article in English | IMSEAR | ID: sea-3148

ABSTRACT

14 patients who underwent balloon valvoplasty had trans-pulmonic gradient evaluated by continuous wave Doppler echocardiography. Maximum systolic gradients measured from Doppler flow velocities were correlated with peak to peak gradient obtained at cardiac catheterisation. Prior to valvoplasty, there was good correlation between the Doppler maximum gradient (92.85 +/- 34.7mm Hg) and the peak to peak catheter gradient (105.57 +/- 56.60 mm Hg), (r = 0.91, p = less than 0.001). Immediately after balloon valvoplasty, the maximum Doppler gradient did not correlate with the peak to peak catheter gradient (r = 0.33, p = NS). Exclusion of patients with infundibular gradients improved the correlation coefficient between the Doppler maximum and peak to peak catheter gradient to 0.69. At late restudy following valvoplasty, when regression of infundibular stenosis was noted in 6 out of 8 patients, the Doppler maximum and catheter peak to peak gradient had excellent correlation (r = 0.97, p = less than 0.001). In patients with lone valvular gradient immediately following valvoplasty and at late restudy, maximum Doppler gradients correlated well with catheter gradients in 14 estimations (r = 0.66, p = less than 0.01). This study shows that the non-invasive quantification of pulmonary valve stenosis can be reliably undertaken, using continuous wave Doppler echocardiography before balloon valvoplasty and during follow-up, after the procedure when the infundibular stenosis has regressed. The presence of an infundibular gradient immediately after balloon dilatation makes the Doppler prediction less reliable.


Subject(s)
Adolescent , Adult , Child , Child, Preschool , Echocardiography, Doppler , Female , Humans , Male , Predictive Value of Tests , Pulmonary Valve Stenosis/therapy
SELECTION OF CITATIONS
SEARCH DETAIL